Qolsys Pre-Wired Fire Module
$200.00
The Qolsys Pre-Wired Fire Module offers a cost effective way of integrating hardwired security & smoke detector zones with the IQ Panel 2/2+. Whereas the standard Qolsys 16 Zone Takeover Module doesn’t support fire zones. In addition, it includes backup battery charging, 500mA of 12volt auxiliary power, an on-board siren relay, built-in status LED’s for each zone as well as support for up to 10 two-wire smoke detectors. Furthermore, normally Open and Normally Closed contacts are supported as well as powered zones like motion sensors and glass break detectors.
Description
Qolsys Pre-Wired Fire Module Description:
The Qolsys Pre-Wired Fire Module offers a cost effective way of integrating hardwired security & smoke detector zones with the IQ Panel 2/2+. Whereas the standard Qolsys 16 Zone Takeover Module doesn’t support fire zones. In addition, it includes backup battery charging, 500mA of 12volt auxiliary power, an on-board siren relay, built-in status LED’s for each zone as well as support for up to 10 two-wire smoke detectors. Furthermore, normally Open and Normally Closed contacts are supported as well as powered zones like motion sensors and glass break detectors. It does not come with the back up battery so you will want to choose either the 5Ah or the 7Ah to go with it.
Main Features
- Encrypted sensor technology protects signals sent to the IQ Panel while still providing support for legacy 319.5 systems
- Supports up to ten two wire smoke detectors
- Includes LED lighted zones for ease of “learn-in” installation/troubleshooting
- EOL supervision using 4.7K Ohm resistors (included)
- Supports up to 500 Milliamps of power for hardwired motion detectors, glass break detector, as well as sirens
- Lastly, charging circuit for back-up battery, fully supervised with power outage recovery
SPECIFICATIONS
- Input Voltage: 16.0VDC Plug-In Transformer Backup Battery: 12VDC 5AH Max (optional) Dimensions: 5.5” X 3.5”
- Operating Temperature: 32 to 122F (0 to 50C)
- Humidity: 95% RH Max
- EOL Supervision: 4.7K Ohm
- Input Zones: 15 N/O or N/C
- Smoke Zone: 1 two-wire smoke loop, 10 detectors max.
- Compatible with Hardwired 2-wire Smoke and Heat Detector with Siren, Hardwired 2-wire Smoke and Heat Detector, and ADT Hardwired Smoke Detector
- Auxiliary Voltage Output: 12VDC @ 500mA Max
- Lastly, the Relay Contact uses 60VDC/1A Max drives siren
How to add to your Qolsys Panel
- Install the Antenna and the power and back up battery
- Connect zones with 4.7k resistor
- Wire tamper switch with a switch or a piece of wire.
- Clear or factory reset by holding down the factory reset button while powering it up
- Then press the eol learn button until you see all leds light up and then turn off (eol cal will turn on letting you know it is in learn mode)
- Now put your Qolsys panel in auto learn mode
- Trip the tamper to add it as a translator
- Trip each zone, one at a time and learn them into the panel. (the led will stay lit until you exit learn mode after you learn a zone in)
- Once you are done learning in zones push the eol learn button again
- If you are using the siren output make sure to put a wire from AUX out to In Siren. then connect the siren wires to ground (black) and out (red)