Honeywell Wireless Commercial Sensor is a universal contact-monitoring transmitter that can be used with household and commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations and remote duct detectors. Upon activation, it emits an RF signal to a control panel, sending a burglary or fire alarm to a central station.
Description
Description:
Honeywell Wireless Commercial Sensor is a universal contact-monitoring transmitter that can be used with household and commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations and remote duct detectors. Upon activation, it emits an RF signal to a control panel, sending a burglary or fire alarm to a central station.
Features:
The Honeywell Wireless Commercial Sensor has three unique input loops (zones)
The first loop (primary loop) supervises and typically used for high-priority alarm reporting such as commercial fire or burglary (reporting transmission every four seconds)
Furthermore, The second loop is the built-in, normally closed reed switch used in conjunction with magnet
In addition, The third loop is another normally closed household burglary loop. All three loops .
A fourth (automatically enrolled) loop contains two tamper switches.
UL Listed for residential and commercial fire and burglary
Compatible with Honeywell as well as Vista 128
Mounting:
1. Remove the transmitter cover by inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit (on the right side closest to the cover’s decorative ribs and twisting).
2. Disengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the mounting plate release hole and pushing the locking tab out. Furthermore, Slide the mounting plate downward along the case back.
3. Feed the wires through the concealed wiring entry hole on one corner of the plate. Mainly If your using concealed wiring.
4. Install the mounting plate, with its caseholding posts pointing up, in the location selected as described in theinstallation instructions. Use the two flat-head screws supplied.
5. Set the DIP switch (after the control panel has enrolled the transmitter’s input ID’s) for the desired primary loop characteristics, as described in the table on the following page.
Dimensions: – 1-9/16″ W x 3-1/2″ H x 1-3/16″ D (40mm x 89mm x 30mm) – Battery 3v Lithium
Maria Mac –
I recently installed Honeywell’s wireless temperature sensors in my commercial building, and I have to say, I’m impressed. The installation process was quick and easy, and the sensors have been working flawlessly ever since. I love that I can monitor the temperature in various parts of the building from a single control system, and the wireless technology means I don’t have to worry about messy and expensive wiring. Overall, I highly recommend Honeywell’s wireless commercial sensors for anyone looking for a reliable and cost-effective monitoring solution