$17.00
ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals is a recessed door contact designed specifically for steel doors. Normally recessed door contacts cannot be used in steel doors because the steel door interferes with the magnet. However, ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals is much larger and therefore will work reliably even when installed inside a steel door. You can choose between a white contact or a brown contact.
ADT Hardwired Recessed Steel Door Sensor 3/4 with Terminals is a recessed door contact designed specifically for steel doors. Normally recessed door contacts cannot be used in steel doors because the steel door interferes with the magnet. However, ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals is much larger. Therefore, will work reliably even when installed inside a steel door. You can choose between a white contact or a brown contact.
Just like the ADT Hardwired Recessed Door Sensor 3/4″ with Terminals , the ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals uses screw terminals to connect the contact to a wired zone on your alarm control panel.
ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals utilizes a Form A, SPST, normally closed internal reed switch which has a rating of 100mA at 24VDC. When the corresponding magnet energizes the contact, the contact loop is closed and the alarm control panel is happy. If the steel door opens, the magnet is pulled away from the ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals and the contact loop opens which triggers an alarm. To keep the contact loop closed, you must ensure that the magnet is not further than 1/2” from the contact when the steel door is closed.
First, connect your alarm wire to the (2) screw terminals at the end of the ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals recessed contact. Then, press the recessed contact into the hole in the steel door frame so that the end cap is flush with the edge of the door. Complete the installation by pressing the magnet into the corresponding hole in the steel door. When you are done, the magnet should be directly across from the contact when the steel door is shut. To avoid misalignment your ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals steel door recessed contact and magnet. We also suggest marking your holes before drilling.
ADT Hardwired Recessed Steel Door Sensor 3/4″ with Terminals
3/4″ recessed with 3/4″ magnet and terminals
1/2″ gap in steel
Staggered T terminals ensure a secure electrical connection
Specifications:
Switch Type: Form A (SPST) Reed
Contact Rating: 100ma @ 28VDC
Check out the other Hardwired Contacts on this page.