Shop
CDMA Interactive Gateway Module
$300.00
This Product is no longer available. This new Universal Alula Communicator is compatible and a great replacement.
The CDMA Interactive Gateway Module connects panels to GSM Network. No need for a landline or internet connection. Additionally, it enables Alarm Reporting, Interactive Control Functions, and Ethernet data reliability. It also includes The Z-Wave communicator, which allows automation of doors, lights, and thermostats.
But if this isn’t what you’re looking for, please take a look at some of our other Resolution products.
Out of stock
Description
The CDMA Interactive Gateway Module connects panels to GSM Network. No need for a landline or internet connection. Additionally, it enables Alarm Reporting, Interactive Control Functions, and Ethernet data reliability. It also includes The Z-Wave communicator, which allows automation of doors, lights, and thermostats.
But if this isn’t what you’re looking for, please take a look at some of our other Resolution products.
Features:
- Connects to the panel keypad bus
- Field switchable to support DSC PowerSeries, Honeywell Vista, NX, or also GE Interlogix Concord.
- Enables both alarm reporting and interactive arming from smartphones.
- Optional Z-Wave card for added home automation features.
Key Instructions
- The same unit works for Vista, Power Series, Concord 4.
- Selectable switch determines panel compatibility.
- DO NOT MOUNT INSIDE METAL CAN – there are radios on the boards that need to be in free-air to communicate.
- Should connect communicator to a 12V power supply with battery backup, such as the control panel’s aux power output.
- The communicator should be mounted in a location that will optimize cellular signal strength. Mount as high in the building as possible.
- CDMA Interactive Gateway Module communicates with the Vista.
Operation:
- Event Reporting: Events are reported to both the monitoring receiver and the interactive server. All events use Contact ID reporting codes. It reports following events by default: Alarms System Low Battery, Alarm cancels System Low Battery Restoral, Openings AC Power Fail (delayed by some panels), Closings AC Power Restoral (delayed by some panels).
- Vista Only: Can enable additional events for reporting if desired by enabling the desired event reports in system programming.
- Interactive Control: You can remotely control the system through the interactive platform. The arm/disarm control and status applies to partition 1 only.
- Z-Wave: Can control Z-Wave devices via the Interactive function.